Tornado serials combines single-point probing and analog scanning in a single high performance measuring machine also can equipped with contact and non-contact probe system. Based on the new generation of controller combines and optimizes temperature and accuracy compensation systems and advanced algorithms to support high-speed, high-accuracy analog open and closed loop scanning.
- Granite fixed worktable, X&Z axis beam has aviation aluminum technology. This structure is the best solution to lighten main carriage’s weight and improve main carriage’s stability and rigidity, so can greatly improves CMM’s performance.
- Granite worktable with integral “dovetail" guide in Y axis, eliminate the pitch and yaw ,also provides superior motion stability.
- Z axis air-balance with self-protection ,improve motion capability.
- Advanced synchronous belt drive system with non-slip and high stiffness, ensures high stabilit, lower noise.
- High precise, rigid, and pre-loaded air bearings on all axes, can ensure the guidance never be damped
- Transmission system uses high-power DC servo motor and new double level tape reducer to ensure rapid and accurate axes
- RENISHAW steel scale
- Famous parts from all over the world are used in every important sub systems
性能指標 Performance Specifications
行程范圍(mm)
Measuring Strokes
外形尺寸(mm)
Overall Dimension
主機重量
(Kg)
Machine Weight
被測工件重量
(Kg)
Max. Part Weight
X
Y
Z
Lx
Ly
Lz
500
600
400
1100
1340
2240
700
500
精度指標:(根據(jù)ISO10360-2坐標測量機的性能評定標準)(Accuracy is according to ISO 10360 – 2)
允許示值誤差MPEE (μm)
Maximum permissible error of indication of a CMM for size measurement (μm)
允許探測誤差MPEP (μm)
Maximum permissible Probing Error (mm)
2.1 + 3.3L/1000
2.2
動態(tài)性能Dynamic Performance
3D運動速度(mm/s)3D positioning speed
3D運動加速度(mm/s2) 3D acceleration
750
1800
環(huán)境條件要求 Environment Specifications:
測量機室溫度要求:Room Required Specifications
房間溫度 (溫控間) Room Temperature
18~22°C
溫度梯度(時間) Temperature Gradient (in time)
1°C /h
溫度梯度(時間) Temperature Gradient (in time)
2°C /24h
溫度梯度(空間)Temperature Gradient (in the volume)
1°C /m
測量機室濕度要求:Humidity Required Specifications
空氣相對濕度Relative humidity
55-65%
氣源要求:Air Supply System Required Specifications
最小供氣壓力Min. air pressure
8 bar [0.8 MPa]
耗氣量Air consumption
0.12-0.45m3/min
電源要求:Electrical requirements
電壓Voltage
220 V ± 10%
頻率Frequency
50/60 Hz
耗電量 (Max Power consumption)
1500VA
電流Current
15 A
允許的的地面振動 Allowed Maximum Floor Vibration
頻率范圍 (Frequency Range)
0 ~ 19 Hz 19~75 Hz > 75 Hz
振幅 (Maximum Amplitude)
0.0011 mm 0.0011~0.002 mm0.002 mm
用電設(shè)備要求接地可靠:接地電阻小于4歐姆
A good earth ground (less than 4 W) is required for reliable operation of the electrical controls.
備注:滿足環(huán)境條件要求的方法具體可參考《機房施工指南》
Note: The Site Preparation Guide will help customer to know how to reach the Room Requirements.