輸入數(shù)據(jù)
| AC輸入電壓 | AC 100 - 240V (-15%/+10%) |
|---|---|
| DC輸入電壓 | DC 110V - 150V (± 20%) |
| 諧波校正 | 主動式 |
| 功率因數(shù) | 0.97 |
| 輸入浪涌電流抑制 | 主動式 |
| 輸入浪涌電流 | 6A / 9A |
| 外部輸入保險絲推薦 | B-6A / C-6A |
輸出數(shù)據(jù)
| 額定電壓 | 24Vdc |
|---|---|
| 調(diào)壓范圍 | 24 - 28V |
| 輸出電流范圍 | 10 - 8.6A |
| 輸出電流 | 8.6A 當(dāng) 28V |
| 10A 當(dāng) 24V | |
| 輸出功率 | 240W |
| 功率儲備 | 20% 額外功率 |
| 降額 | 6W/°C 為 >+60°C |
| 電壓紋波與噪聲 值 | 50mVpp |
概述
| 尺寸(寬x高x深) | 39mm x 124mm x 117mm |
|---|---|
| 每臺的重量(凈重) | 620g |
| 工作溫度范圍 | -25°C 至 70°C |
| 安裝方式 | DIN導(dǎo)軌 |
| 轉(zhuǎn)換效率,典型值 | 95.2% |
| 功率損耗,典型值 | 12.1W |
| 平均時間 SN 29500 @ 40°C (h) | 661000h |
| 連接端子類型 | 彈壓式接線端子 |
| DC-OK信號 | 有 |
如何使用EPLAN .edz文件
1. Download file from website to desktop
2. Unzip file3. Open items folder
This folder contains all files that can also be downloaded directly from the EPLAN platform.
2. Unzip file3. Open items folder
This folder contains all files that can also be downloaded directly from the EPLAN platform.
Marine DNV
- 已獲2MOPP安全批準(zhǔn),根據(jù)IEC 60601-1(第三版)可用于醫(yī)療
- 通過EMC測試,根據(jù)IEC 60601-1-2(第四版)可用于醫(yī)療
- 快速連接的彈壓式接線端子
- AC 100-240V 寬范圍輸入
- 寬度僅39mm
- 高達(dá)到95.2%, 非滿載時效率依舊
- 20%輸出功率備儲
- HiccupPLUS 安全過載模式
- 簡單保險絲跳斷,由高過載峰值電流提供
- 主動式功率因數(shù)校正 (PFC)
- 最小化的浪涌電流沖擊
- 滿輸出功率,當(dāng)溫度為 -25至+60°C
- DC-OK信號繼電器觸點(diǎn)
| 訂貨號 | CP10.241-M1 |
|---|---|
| 產(chǎn)品狀態(tài) | 常備庫存 |
| UPC碼 | |
| 質(zhì)保(月) | 36 |
| 原產(chǎn)國 | 中國/捷克共和國 |
| 包裝單位 | 1 臺 |
| 每臺的重量(凈重) | 620g |
| E分類 | eClass 5.1 |
| eClass 6.x | |
| eClass 7.x | |
| eClass 8.0 | |
| eClass 9.0 | |
| ETIM 4.0 EC000599 | |
| ETIM 5.0 EC002540 | |
| HS編碼 |